Integrated Current Sensor FHS AH 600
Definition
The FHS AH current sensor is LEM new SMD open loop current sensor based on the Hall effect principle. It benefits from
improvement in sensitivity and accuracy temperature stress compensation. It is suitable for DC, AC, pulsed and mixed current
measurements. This field sensor has built in Integrated Magnetic Circuit (IMC), that gives an optimum sensitivity, to offer flexibility
in compact design without requiring external magnetic core concentrator. It is a perfect solution to measure current flowing in a
conductor such as a PCB track. High isolation between the primary circuit and transducer electronics can be obtained with a
double-sided PCB.
Main features & Advantages
Typical applications
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Hall effect current sensor with Integrated Magnetic
Concentrator (IMC)
Magnetic field measurement range ±3.3 mT
Supply voltage 5 V
Low power consumption
High bandwidth: 160 kHz
Sensitivity range up over to 200 mV/A
Isolated current measurement
Small footprint with standard SOIC8 surface mount
PCB
Low cost, Small size
Excellent linearity
No power loss in primary circuit
Internal reference voltage
Small drives
BMS
Motor control
UPS
HVAC
White goods.
PCB track current measurement
Standards
•
AECQ 100 pending
Figure 1 FHS AH package – SOIC-8
(Not to scale - For illustration: not representative)
Page 1 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Application circuit and pinout
Figure 2 Application circuit
External circuit example
Min
Typ
Max
Unit
CSupply
47
100
nF
COUT
4.7
6
nF
CREF
47
nF
R I_OCD
4.7
50
kΩ
R E_OCD
4.7
50
kΩ
RE
100
kΩ
R E REF
100
kΩ
CSupply, COUT and CREF should be mounted as close as to the pins.
Ideally, R E REF + R E should have a value around 200 kΩ due to current limitation on UREF.
UOUT - UREF is positive when primary current flowing under FHS AH from pin 4/5 to the pin 1/8.
FHS can be directly mounted above the PCB track in which the current to be measured flows.
Pins
number
Name
Description
1
UREF
Reference voltage
2
UOUT
Output voltage
3
GND
Ground terminal
4
UC
Supply voltage
5
NC
Not Connected or GND
6
OCD EXT
External OCD
7
OCD INT
Internal OCD
8
UE OCD
External OCD threshold
voltage terminal
Page 2 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Block diagram
Figure 3 Block diagram FHS AH
Absolute maximum rating
Parameter
Symbol
Unit
Min
Ambient operating temperature
TA
°C
-40
125
Ambient storage temperature
TA st
°C
-55
165
Maximum junction temperature
TJ max
°C
165
Output sink current
mA
-50
Output source current
mA
25
Magnetic flux density
Bmax
T
Typ
-3
Max
Comment
TBC
3
Absolute maximum ratings apply at 25 °C unless otherwise noted.
Stresses above these ratings may cause permanent damage
Exposure to absolute maximum ratings for extended periods may degrade reliability.
Environmental and mechanical characteristics
Parameter
Maximum supply voltage
Electrostatic discharge voltage (HBM -Human Body Model)
Mass
Symbol
Unit
Value
UC max
V
8
UESD HBM
kV
2
m
g
0.08
Page 3 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Electrical Data
At TA = 35 °C, UC = +5 V, RL = 100 kΩ, unless otherwise noted (see Min, Max, Typ, definition paragraph in “Terms and
definitions” chapter).
Parameter
Symbol
Unit
Min
Typ
Max
DC supply voltage
UC
V
4.5
5
5.5
Current consumption
IC
mA
12
14
19
Magnetic flux density measuring range
BM
mT
Output voltage in a flux density B
Uout
V
Linearity error 0 … BM
εL
% of BM
Nominal sensitivity
SN
mV/mT
600
Sensitivity error
εS
%
±0.5
TCS
ppm/K
Temperature coefficient of S
Lifetime S drift
±3.3
Comment
−40 °C ... 125 °C , without
RL
UC > 4.6 V
Uref + UO E + (SN x B)
-0.5
0.5
-200
%
±1
200
−40 °C ... 125 °C, referred
to 35 °C
±1
TBC
Internal reference voltage @ B = 0 T
Uref
V
2.48
2.5
2.52
Output internal resistance of Uref
Rref
Ω
120
200
333
−40 °C ... 125 °C
TCUref
ppm/K
-150
150
−40 °C ... 125 °C, referred
to 35 °C
±2
TBC
Temperature coefficient of Uref
Lifetime Uref drift
mV
Electrical offset
UO E
mV
-10
10
Lifetime UO E drift
mV
±2.5
Remanent filed
µT
15
After ±BM
0.1
−40 °C ... 125 °C, referred
to 35 °C
Temperature coefficient of UO E
TCUO E
mV/K
-0.1
Output internal resistance of Uout
Rout
Ω
Noise voltage spectral density
Uno
µV/Hz1/2
Delay time @ 10 % of BN
tD10
µs
1.6
Input signal rise time 2 us
Delay time @ 90 % of BN
tD90
µs
1.4
Input signal rise time 2 us
160
@ -3 dB
Frequency bandwidth
BW
kHz
100
@ -1 dB
5
DC
TBC
17
Overcurrent detection (OCD)
Page 4 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Overcurrent detection is a feature included on FHS AH product in order to detect high peaks of currents happening during
operation. Two overcurrent detection types are included in this product: Internal OCD and External OCD:
Parameter
Symbol
Unit
Min
Typ
Max
Comment
Internal OCD
Internal OCD detection threshold
II OCD Th
A
TBC
±IPN
Internal OCD threshold error
ε I OCD Th
%
±8
Referred to
B @UOUT-UREF=0.8 V
Internal OCD output on resistance
Ron I OCD
70
95
150
Internal OCD output hold time
thold I OCD
s
7
10
14
tD I OCD
s
1.3
2.1
±12.5
±50
Internal OCD delay time
Open drain output, active
low
External OCD
External OCD detection threshold
IE OCD Th
A
External OCD threshold error
ε E OCD Th
%
External OCD output on resistance
Ron E OCD
External OCD output hold time
thold E OCD
s
10
tD E OCD
s
10
External OCD delay time
±5
35
200
B @UOUT-UREF=0.8 V
280
Open drain output, active
low
Page 5 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
𝑈𝐸 𝑂𝐶𝐷 = 𝑅
𝑅𝐸
𝐸 +𝑅𝐸 𝑅𝐸𝐹
∙ 𝑈𝑅𝐸𝐹
=> 𝐵𝐸 𝑂𝐶𝐷 =
𝑈𝑅𝐸𝐹 −𝑈𝐸 𝑂𝐶𝐷
𝑆𝑁
𝑤𝑖𝑡ℎ 0.5 < 𝑈𝐸 𝑂𝐶𝐷 < 𝑈𝑅𝐸𝐹 − 0.5Internal
OCD behavior:
Figure X Internal OCD behaviour
Page 6 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
External OCD behavior:
Figure X External OCD behaviour
Definition of typical, minimum and maximum values
Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values
shown in “typical” graphs.
On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower
limits and a probability for measured values to lie within this interval.
Unless otherwise stated (e.g., “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that the
probability for values of samples to lie in this interval is 99.73 %.
For a normal (Gaussian) distribution, this corresponds to an interval between −3 sigma and +3 sigma. If “typical” values are not
obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to
an interval between −sigma and +sigma for a normal distribution.
Typical, maximal, and minimal values are determined during the initial characterization of the product.
Page 7 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Noise
Figure X Output voltage noise
Linearity
Figure X Linearity error @35 °C
Figure X Linearity error @125 °C
Di/dt
Time base: 1 µs/div
Primary current
UOUT
Figure X di/dt
Page 8 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Bandwidth
Figure X Bandwidth
Page 9 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Terms and definitions
Sensitivity and linearity
To measure sensitivity and linearity, the primary current (DC) is cycled from 0 to BM, then to − BM and back to 0
(equally spaced BM /10 steps).
The sensitivity S is defined as the slope of the linear regression line for a cycle between ± BM.
The linearity error εL is the maximum positive or negative difference between the measured points and the linear
regression line, expressed in % of BM.
Delay times
The delay time tD 10 @ 10 % and the delay time tD 90 @ 90 % with respect to the primary are shown in the next
figure.
Both slightly depend on the primary current di/dt. They are measured at nominal voltage output.
Figure X tD 10 (delay time @ 10 %) and tD 90 (delay time @ 90 %).
Typical connection diagram and ground plane
Good EMC practice requires the use of ground planes on PCBs. In drives where high dv/dt transients are present, a ground
plane between the primary conductor and FHS AH will reduce or avoid output perturbations due to capacitive currents.
However, the ground plane has to be designed to limit eddy currents that would otherwise slow down the response time. The
effect of eddy currents is made negligible by cutting the copper plane under the package as shown in bellow figure.
Figure X Top side copper plane has a cut under the IC to optimize response time
Page 10 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Application information
Basic operation: example with a long thin conductor
FHS AH is a galvanically isolated current transducer. It senses the magnetic field generated by the measured current and
transforms it into an output voltage.
If the current is bidirectional, FHS AH will sense the polarity of the magnetic field and generate a positive or negative output
voltage relative to the reference voltage.
A simple case is presented which illustrates the current to magnetic field and then to output voltage conversion.
A current flowing in a long thin conductor generates a flux density around it: 𝐵
𝜇
= 2𝜋0 ∙
𝐼𝑃
𝑟
(𝑇)
With:
•
•
•
IP the current to be measured (A)
r the distance from the center of the wire (m)
μ0 the permeability of vacuum (physical constant, μ0 = 4.π. 10-7 (H/m)
Figure X FHS AH orientation to measure the magnetic field generated by a current along a conductor
If FHS AH is now placed in the vicinity of the conductor (with its sensitivity direction colinear to the flux density B), it will sense
the flux density and the output voltage will be:
𝑈𝑂𝑈𝑇 = 𝐺𝐵 ∙ 𝐵 = 𝐺𝐵 ∙
𝜇0 𝐼𝑃
𝐼𝑃
∙ = 1.2 ∙ 10−4 ∙ (𝑉)
2𝜋 𝑟
𝑟
where GB is the FHS AH magnetic sensitivity (600 V/T).
The sensitivity is therefore:
𝐺=
𝑈𝑂𝑈𝑇
𝐼𝑃
=
1.2 ∙ 10−4
𝑟
(𝑉/𝐴)
The next graph shows how the output voltage decreases when r increases.
Note that the sensitivity also depends on the primary conductor shape.
Page 11 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Figure X Sensitivity versus the distance between the conductor and the FHS AH sensing elements
The example above is of limited practical use as most conductors are not round and thin but explains the principles of FHS AH
operation.
The measuring range limit (IPM) is reached when the output voltage (UOUT - UREF ) reaches 2 V.
This limit is due to electrical saturation of the output amplifier. The input current or field may be increased above this limit without
risk for the circuit.
Recovery will occur without additional delay (same response time as usual).
The maximum current that can be continuously applied to the transducer (IPM) is only limited by the primary conductor carrying
capacity.
Single track on PCB
The main practical configurations will now be reviewed, and their main features highlighted.
The use of FHS AH to measure a current flowing in a track provides the following advantages:
•
•
•
•
Isolation is guaranteed by PCB design. If the primary track is placed on the opposite (bottom) side of the PCB, the
isolation can be very high
stable and reproducible sensitivity
inexpensive
large input currents (up to about 100 A).
Figure X Principle of FHS AH used to measure current in a PCB track
Page 12 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Figure X Sensitivity versus track width and versus distance between the track and the FHS AH sensing elements (TBC)
The sensitivity depends on the track width and distance, as shown in above figure.
The maximum current that can be safely applied continuously is determined by the temperature rise of the track.
The use of a track with varying width gives the best combination of sensitivity and track temperature rise.
Multi-turns
For low currents (under 10 A), it is advisable to make several turns with the primary track to increase the magnetic field generated
by the primary current.
Cable or busbar
For very large currents (>50A), FHS AH can be used to measure the current flowing in a cable or busbar.
The position of FHS AH relatively to the conductor has to be stable to avoid sensitivity variations.
Figure X Example with cable or busbar
Accuracy considerations
Several factors influence the output accuracy of FHS AH as a current transducer:
•
The sensitivity of the FHS AH
•
The distance and shape of the primary conductor
•
The circuit output offset
•
The circuit non-linearity
•
Stray fields
The sensitivity of the FHS AH is calibrated during production at 600 V/T. As already mentioned, the distance and shape of the
primary conductor also influence the sensitivity.
No relative movement of the primary conductor to FHS AH should be possible.
To avoid differences in a production, the position and shape of the primary conductor and circuit should always be identical.
Page 13 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
The magnetic fields generated by neighboring conductors, the earth’s magnetic field, magnets, etc. are also measured if they
have a component in the direction to which FHS AH is sensitive (see figure X).
As a rule, the stronger the field generated by the primary current, the smaller the influence of stray fields and offset.
The primary conductor should therefore be designed to maximize the output voltage.
PCB footprint & dimensions (in mm)
Figure X SOIC8, Package dimensions
Notes:
All dimensions are in millimeters (angles in degrees)
* Dimensions do not include mold flash, protrusions or gate burrs (shall not exceed 0.15 per side)
** Dimension does not include interleads flash or protrusion (shall not exceed 0.25 per side)
*** Dimension does not include dambar protrusion.
Allowable dambar protrusion shall be 0.08 mm total in excess of the dimension at maximum material condition.
Dambar cannot be located on the lower radius of the foot.
Mechanical characteristics
Hall plate position
Page 14 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Figure X Hall plate position
Soldering
Recommended reflow soldering profile●●as standard: IPC/JEDEC J-STD-020 revision C
Tape and Reel dimensions
Page 15 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Packaging
Page 16 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Safety
⚠
Caution
If the device is used in a way that is not specified by the manufacturer, the protection provided by the device may be
compromised.
Always inspect the electronics unit and connecting cable before using this product and do not use it if damaged.
Mounting assembly shall guarantee the maximum primary conductor temperature, fulfill clearance and creepage distance,
minimize electric and magnetic coupling, and unless otherwise specified can be mounted in any orientation.
Caution, risk of electrical shock
This transducer must be used in limited-energy secondary circuits SELV according to IEC 61010-1, in electric/electronic
equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating
specifications.
Use caution during installation and use of this product; certain parts of the module can carry hazardous voltages and high
currents (e.g., power supply, primary conductor).
Ignoring this warning can lead to injury and or/or cause serious damage.
If applicable: De-energize all circuits and hazardous live parts before installing the product.
All installations, maintenance, servicing operations and use must be carried out by trained and qualified personnel practicing
applicable safety precautions.
This transducer is a build-in device, whose hazardous live parts must be inaccessible after installation.
This transducer must be mounted in a suitable end-enclosure.
Besides make sure to have minimum 30 mm between the primary terminals of the transducer and other neighboring
components.
If applicable: Main supply must be able to be disconnected.
If applicable: Always inspect the flexible probe for damage before using this product.
If applicable: Never connect or disconnect the external power supply while the primary circuit is connected to live parts.
If applicable: Never connect the output to any equipment with a common mode voltage to earth greater than 30 V.
If applicable: Always wear protective clothing and gloves if hazardous live parts are present in the installation where the
measurement is carried out.
This transducer is a built-in device, not intended to be cleaned with any product. Nevertheless, if the user must implement
cleaning or washing process, validation of the cleaning program has to be done by himself.
If applicable: When defining soldering process, please use no cleaning process only.
ESD susceptibility
The product is susceptible to be damaged from an ESD event and the personnel should be grounded when handling it.
Do not dispose of this product as unsorted municipal waste. Contact a qualified recycler for disposal.
If CE marking not applicable: Although LEM applies utmost care to facilitate compliance of end products with applicable
regulations during LEM product design, use of this part may need additional measures on the application side for compliance
with regulations regarding EMC and protection against electric shock.
Therefore, LEM cannot be held liable for any potential hazards, damages, injuries or loss of life resulting from the use of this
product.
Underwriters Laboratory Inc. recognized component
Page 17 of 18
G21021C SDA/Version 0
N°98.11.11.807.0/Version 0
LEM reserves the right to carry out modifications on its transducers
to improve them without prior notice
LEM INTERNATIONALE SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES
SWITZERLAND
www.lem.com
Version history
Date
Version
2022/01/07
V0
Comment
Specimen
Page 18 of 18
G21021C SDA/Version 0